Fall
Hazards from Scaffolding - Page 4 |
|
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.451(g)(1): Fall protection not
provided.
1926.451(b)(1): Platform not fully planked.
Corrective Action: Provide guardrail systems, safety net
systems, or personal fall arrest systems. Fully plank platforms. |
|
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.451(g)(1): Worker standing on the top
rail of a scissors lift without fall protection.
Corrective Action: Protect employee by the use of a personal
fall arrest system or guardrail system. Train employee to recognize fall
hazard. |
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.501(b)(1), 1926.451(g)(1):
Employee on top of wall w/o fall protection. Fall hazard of about 22 feet to
concrete floor below.
Corrective Action: Employer needs to provide a safe work
platform or fall protection system. Reference 1926.502 for Fall protection
systems and criteria and practices. |
|
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.451(g)(1): Fall protection not
provided.
Corrective Action: Provide guardrail system. |
|
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.451(g)(1): Fall protection not
provided.
1926.451(b)(1): Platforms not fully planked.
1926.451(c)(2): Unstable objects were used as scaffold support.
Corrective Action: Provide guardrail system or personal fall
arrest system. Fully plank platforms. Provide adequate scaffold support. |
|
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.451(g)(1): Fall protection not
provided.
1926.451(b)(1): Platform not fully planked.
Corrective Action: Provide guardrails. Fully plank platform. |
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.451(g)(1): Employee was working
on a carpenters' bracket scaffold 20 feet high without fall protection.
Corrective Action: Install guardrails |
|
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.451(g)(1): Fall protection not
provided.
1926.451(b)(1): Platforms not fully planked.
1926.451(e): Employee riding hoist line.
Corrective Action: Provide guardrail system or personal fall
arrest system. Fully plank platforms. Provide safe access. |
 |
Hazard: Lack of fall protection for
employees on fabricated frame scaffolds.
Standard violated: 1926.451(g)(1)(vii): employees
exposed to a 35-foot fall hazard from a scaffold while stacking blocks prior
to overhand bricklaying operations.
Corrective Action: Provide guardrails or personal fall
arrest systems to protect employees. |
 |
Hazard: Hazard of
lifelines breaking resulting in fall hazard for employees.
Standard violated: 1926.451(g)(3)(i): lifelines not
protected from sharp edges.
Corrective Action: Lifelines relocated to protect against sharp
edges. |
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.452(j)(1-7): This photo does not
document a violation. The employees are installing metal siding on housing
units, working from pump jack scaffolds. The scaffolds are equipped with a
guardrail and safety net system for fall protection. The employer does not
have end rails up yet, but they are not at 10' in these photos.
Corrective Action: N/A |
 |
Hazard: Fall from
scaffold.
Standard violated: 11926.452(j)(1-7): This photo does not
document a violation. The employees are installing metal siding on housing
units, working from pump jack scaffolds. The scaffolds are equipped with a
guardrail and safety net system for fall protection. The employer does not
have end rails up yet, but they are not at 10' in these photos.
Corrective Action: N/A |
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.452(j)(1-7): This photo does not
document a violation. The employees are installing metal siding on housing
units, working from pump jack scaffolds. The scaffolds are equipped with a
guardrail and safety net system for fall protection. The employer does not
have end rails up yet, but they are not at 10' in these photos.
Corrective Action: N/A |
 |
Hazard: Fall from
scaffold.
Standard violated: 1926.452(j)(1-7): This photo does not
document a violation. The employees are installing metal siding on housing
units, working from pump jack scaffolds. The scaffolds are equipped with a
guardrail and safety net system for fall protection. The employer does not
have end rails up yet, but they are not at 10' in these photos.
Corrective Action: N/A |
|
Return to Main Picture
Page Scaffolds
Page 1 Scaffolds Page 2
Scaffolds Page 3
Scaffolds Page 4 |