1926.1053(a)
General. The following requirements apply to all ladders
as indicated, including job-made ladders.
1926.1053(a)(1)
Ladders shall be capable of supporting the following loads
without failure:
1926.1053(a)(1)(i)
Each self-supporting portable ladder: At least four times
the maximum intended load, except that each extra-heavy-duty type 1A metal
or plastic ladder shall sustain at least 3.3 time the maximum intended
load. The ability of a ladder to sustain the loads indicated in this
paragraph shall be determined by applying or transmitting the requisite
load to the ladder in a downward vertical direction. Ladders built and
tested in conformance with the applicable provisions of appendix A of this
subpart will be deemed to meet this requirement.
..1926.1053(a)(1)(ii)
1926.1053(a)(1)(ii)
Each portable ladder that is not self-supporting: At least
four times the maximum intended load, except that each extra-heavy-duty
type 1A metal or plastic ladders shall sustain at least 3.3 times the
maximum intended load. The ability of a ladder to sustain the loads
indicated in this paragraph shall be determined by applying or
transmitting the requisite load to the ladder in a downward vertical
direction when the ladder is placed at an angle of 75 1/2 degrees from the
horizontal. Ladders built and tested in conformance with the applicable
provisions of appendix A will be deemed to meet this requirement.
1926.1053(a)(1)(iii)
Each Fixed ladder: At least two loads of 250 pounds (114
kg) each, concentrated between any two consecutive attachments (the number
and position of additional concentrated loads of 250 pounds (114 kg) each,
determined from anticipated usage of the ladder, shall also be included),
plus anticipated loads caused by ice buildup, winds, rigging, and impact
loads resulting from the use of ladder safety devices. Each step or rung
shall be capable of supporting a single concentrated load of a least 250
pounds (114 kg) applied in the middle of the step or rung. Ladders built
in conformance with the applicable provisions of appendix A will be deemed
to meet this requirement.
1926.1053(a)(2)
Ladder rungs, cleats, and steps shall be parallel, level,
and uniformly spaced when the ladder is in position for use.
1926.1053(a)(3)
-
1926.1053(a)(3)(i)
Rungs, cleats, and steps of portable ladders (except as
provided below) and fixed ladders (including individual-rung/step ladders)
shall be spaced not less than 10 inches (25 cm) apart, nor more than 14
inches (36 cm) apart, as measured between center lines of the rungs,
cleats and steps.
..1926.1053(a)(3)(ii)
1926.1053(a)(3)(ii)
Rungs, cleats, and steps of step stools shall be not less
than 8 inches (20 cm) apart, nor more than 12 inches (31 cm) apart, as
measured between center lines of the rungs, cleats, and steps.
1926.1053(a)(3)(iii)
Rungs, cleats, and steps of the base section of extension
trestle ladders shall be not less than 8 inches (20 cm) nor more than 18
inches (46 cm) apart, as measured between center lines of the rungs,
cleats, and steps. The rung spacing on the extension section of the
extension trestle ladder shall be not less than 6 inches (15 cm) nor more
than 12 inches (31 cm), as measured between center lines of the rungs,
cleats, and steps.
1926.1053(a)(4)
-
1926.1053(a)(4)(i)
The minimum clear distance between the sides of
individual-rung/step ladders and the minimum clear distance between the
side rails of other fixed ladders shall be 16 inches (41 cm).
1926.1053(a)(4)(ii)
The minimum clear distance between side rails for all
portable ladders shall be 11 1/2 inches (29 cm).
1926.1053(a)(5)
The rungs of individual-rung/step ladders shall be shaped
such that employees' feet cannot slide off the end of the rungs.
1926.1053(a)(6)
-
1926.1053(a)(6)(i)
The rungs and steps of fixed metal ladders manufactured
after March 15, 1991, shall be corrugated, knurled, dimpled, coated with
skid-resistant material, or otherwise treated to minimize slipping.
..1926.1053(a)(6)(ii)
1926.1053(a)(6)(ii)
The rungs and steps of portable metal ladders shall be
corrugated, knurled, dimpled, coated with skid-resistant material, or
otherwise treated to minimize slipping.
1926.1053(a)(7)
Ladders shall not be tied or fastened together to provide
longer sections unless they are specifically designed for such use.
1926.1053(a)(8)
A metal spreader or locking device shall be provided on
each stepladder to hold the front and back sections in an open position
when the ladder is being used.
1926.1053(a)(9)
When splicing is required to obtain a given length of side
rail, the resulting side rail must be at least equivalent in strength to a
one-piece side rail made of the same material.
1926.1053(a)(10)
Except when portable ladders are used to gain access to
fixed ladders (such as those on utility towers, billboards, and other
structures where the bottom of the fixed ladder is elevated to limit
access), when two or more separate ladders are used to reach an elevated
work area, the ladders shall be offset with a platform or landing between
the ladders. (The requirements to have guardrail systems with toeboards
for falling object and overhead protection on platforms and landings are
set forth in subpart M of this part.)
1926.1053(a)(11)
Ladder components shall be surfaced so as to prevent
injury to an employee from punctures or lacerations, and to prevent
snagging of clothing.
..1926.1053(a)(12)
1926.1053(a)(12)
Wood ladders shall not be coated with any opaque covering,
except for identification or warning labels which may be placed on one
face only of a side rail.
1926.1053(a)(13)
The minimum perpendicular clearance between fixed ladder
rungs, cleats, and steps, and any obstruction behind the ladder shall be 7
inches (18 cm), except in the case of an elevator pit ladder for which a
minimum perpendicular clearance of 4 1/2 inches (11 cm) is required.
1926.1053(a)(14)
The minimum perpendicular clearance between the center
line of fixed ladder rungs, cleats, and steps, and any obstruction on the
climbing side of the ladder shall be 30 inches (76 cm), except as provided
in paragraph (a)(15) of this section.
1926.1053(a)(15)
When unavoidable obstructions are encountered, the minimum
perpendicular clearance between the centerline of fixed ladder rungs,
cleats, and steps, and the obstruction on the climbing side of the ladder
may be reduced to 24 inches (61 cm), provided that a deflection device is
installed to guide employees around the obstruction.
1926.1053(a)(16)
Through fixed ladders at their point of access/egress
shall have a step-across distance of not less than 7 inches (18 cm) nor
more than 12 inches (30 cm) as measured from the centerline of the steps
or rungs to the nearest edge of the landing area. If the normal
step-across distance exceeds 12 inches (30 cm), a landing platform shall
be provided to reduce the distance to the specified limit.
..1926.1053(a)(17)
1926.1053(a)(17)
Fixed ladders without cages or wells shall have a clear
width to the nearest permanent object of at least 15 inches (30 cm) on
each side of the centerline of the ladder.
1926.1053(a)(18)
Fixed ladders shall be provided with cages, wells, ladder
safety devices, or self-retracting lifelines where the length of climb is
less than 24 feet (7.3 m) but the top of the ladder is at a distance
greater than 24 feet (7.3 m) above lower levels.
1926.1053(a)(19)
Where the total length of a climb equals or exceeds 24
feet (7.3 m), fixed ladders shall be equipped with one of the
following:
1926.1053(a)(19)(i)
Ladder safety devices;
or
1926.1053(a)(19)(ii)
Self-retracting lifelines, and rest platforms at intervals
not to exceed 150 feet (45.7 m); or
1926.1053(a)(19)(iii)
A cage or well, and multiple ladder sections, each ladder
section not to exceed 50 feet (15.2 m) in length. Ladder sections shall be
offset from adjacent sections, and landing platforms shall be provided at
maximum intervals of 50 feet (15.2 m).
1926.1053(a)(20)
Cages for fixed ladders shall conform to all of the
following:
1926.1053(a)(20)(i)
Horizontal bands shall be fastened to the side rails of
rail ladders, or directly to the structure, building, or equipment for
individual-rung ladders;
..1926.1053(a)(20)(ii)
1926.1053(a)(20)(ii)
Vertical bars shall be on the inside of the horizontal
bands and shall be fastened to them;
1926.1053(a)(20)(iii)
Cages shall extend not less than 27 inches (66 cm), or
more than 30 inches (76 cm) from the centerline of the step or rung
(excluding the flare at the bottom of the cage), and shall not be less
than 27 inches (68 cm) in width;
1926.1053(a)(20)(iv)
The inside of the cage shall be clear of projections;
1926.1053(a)(20)(v)
Horizontal bands shall be spaced not more than 4 feet (1.2
m) on center vertically;
1926.1053(a)(20)(vi)
Vertical bars shall be spaced at intervals not more than 9
1/2 inches (24 cm) on center horizontally;
1926.1053(a)(20)(vii)
the bottom of the cage shall be at a level not less than 7
feet (2.1 m) nor more than 8 feet (2.4 m) above the point of access to the
bottom of the ladder. The bottom of the cage shall be flared not less than
4 inches (10 cm) all around within the distance between the bottom
horizontal band and the next higher band;
1926.1053(a)(20)(viii)
The top of the cage shall be a minimum of 42 inches (1.1
m) above the top of the platform, or the point of access at the top of the
ladder, with provision for access to the platform or other point of
access.
..1926.1053(a)(21)
1926.1053(a)(21)
Wells for fixed ladders shall conform to all of the
following:
1926.1053(a)(21)(i)
They shall completely encircle the ladder;
1926.1053(a)(21)(ii)
They shall be free of projections;
1926.1053(a)(21)(iii)
Their inside face on the climbing side of the ladder shall
extend not less than 27 inches (68 cm) nor more than 30 inches (76 cm)
from the centerline of the step or
rung;
1926.1053(a)(21)(iv)
The inside clear width shall be at least 30 inches (76
cm);
1926.1053(a)(21)(v)
The bottom of the wall on the access side shall start at a
level not less than 7 feet (2.1 m) nor more than 8 feet (2.4 m) above the
point of access to the bottom of the
ladder.
1926.1053(a)(22)
Ladder safety devices, and related support systems, for
fixed ladders shall conform to all of the following:
1926.1053(a)(22)(i)
They shall be capable of withstanding without failure a
drop test consisting of an 18-inch (41 cm) drop of a 500-pound (226 kg)
weight;
1926.1053(a)(22)(ii)
They shall permit the employee using the device to ascend
or descend without continually having to hold, push, or pull any part of
the device, leaving both hands free for climbing;
..1926.1053(a)(22)(iii)
1926.1053(a)(22)(iii)
They shall be activated within 2 feet (.61 m) after a fall
occurs, and limit the descending velocity of an employee to 7 feet/sec.
(2.1 m/sec.) or less;
1926.1053(a)(22)(iv)
The connection between the carrier or lifeline and the
point of attachment to the body belt or harness shall not exceed 9 inches
(23 cm) in length.
1926.1053(a)(23)
The mounting of ladder safety devices for fixed ladders
shall conform to the following:
1926.1053(a)(23)(i)
Mountings for rigid carriers shall be attached at each end
of the carrier, with intermediate mountings, as necessary, spaced along
the entire length of the carrier, to provide the strength necessary to
stop employees' falls;
1926.1053(a)(23)(ii)
Mountings for flexible carriers shall be attached at each
end of the carrier. When the system is exposed to wind, cable guides for
flexible carriers shall be installed at a minimum spacing of 25 feet (7.6
m) and maximum spacing of 40 feet (12.2 m) along the entire length of the
carrier, to prevent wind damage to the system.
1926.1053(a)(23)(iii)
The design and installation of mountings and cable guides
shall not reduce the design strength of the ladder.
..1926.1053(a)(24)
1926.1053(a)(24)
The side rails of through or side-step fixed ladders shall
extend 42 inches (1.1 m) above the top of the access level or landing
platform served by the ladder. For a parapet is continuous, the access
level shall be the top of the parapet.
1926.1053(a)(25)
For through-fixed-ladder extensions, the steps or rungs
shall be omitted from the extension and the extension of the side rails
shall be flared to provide not less than 24 inches (61 cm) nor more than
30 inches (76 cm) clearance between side rails. Where ladder safety
devices are provided, the maximum clearance between side rails of the
extensions shall not exceed 36 inches (91 cm).
1926.1053(a)(26)
For side-step fixed ladders, the side rails and the steps
or rungs shall be continuous in the extension.
1926.1053(a)(27)
Individual-rung/step ladders, except those used where
their access openings are covered with manhole covers or hatches, shall
extend at least 42 inches (1.1 m) above an access level or landing
platform either by the continuation of the rung spacings as horizontal
grab bars or by providing vertical grab bars that shall have the same
lateral spacing as the vertical legs of the rungs.
1926.1053(b)
Use. The following requirements apply to the use of all
ladders, including job-made ladders, except as otherwise indicated:
..1926.1053(b)(1)
1926.1053(b)(1)
When portable ladders are used for access to an upper
landing surface, the ladder side rails shall extend at least 3 feet (.9 m)
above the upper landing surface to which the ladder is used to gain
access; or, when such an extension is not possible because of the ladder's
length, then the ladder shall be secured at its top to a rigid support
that will not deflect, and a grasping device, such as a grabrail, shall be
provided to assist employees in mounting and dismounting the ladder. In no
case shall the extension be such that ladder deflection under a load
would, by itself, cause the ladder to slip off its support.
1926.1053(b)(2)
Ladders shall be maintained free of oil, grease, and other
slipping hazards.
1926.1053(b)(3)
Ladders shall not be loaded beyond the maximum intended
load for which they were built, nor beyond their manufacturer's rated
capacity.
1926.1053(b)(4)
Ladders shall be used only for the purpose for which they
were designed.
1926.1053(b)(5)
-
1926.1053(b)(5)(i)
Non-self-supporting ladders shall be used at an angle such
that the horizontal distance from the top support to the foot of the
ladder is approximately one-quarter of the working length of the ladder
(the distance along the ladder between the foot and the top support).
1926.1053(b)(5)(ii)
Wood job-made ladders with spliced side rails shall be
used at an angle such that the horizontal distance is one-eighth the
working length of the ladder.
1926.1053(b)(5)(iii)
Fixed ladders shall be used at a pitch no greater than 90
degrees from the horizontal, as measured to the back side of the
ladder.
..1926.1053(b)(6)
1926.1053(b)(6)
Ladders shall be used only on stable and level surfaces
unless secured to prevent accidental displacement.
1926.1053(b)(7)
Ladders shall not be used on slippery surfaces unless
secured or provided with slip-resistant feet to prevent accidental
displacement. Slip-resistant feet shall not be used as a substitute for
care in placing, lashing, or holding a ladder that is used upon slippery
surfaces including, but not limited to, flat metal or concrete surfaces
that are constructed so they cannot be prevented from becoming
slippery.
1926.1053(b)(8)
Ladders placed in any location where they can be displaced
by workplace activities or traffic, such as in passageways, doorways, or
driveways, shall be secured to prevent accidental displacement, or a
barricade shall be used to keep the activities or traffic away from the
ladder.
1926.1053(b)(9)
The area around the top and bottom of ladders shall be
kept clear.
1926.1053(b)(10)
The top of a non-self-supporting ladder shall be placed
with the two rails supported equally unless it is equipped with a single
support attachment.
1926.1053(b)(11)
Ladders shall not be moved, shifted, or extended while
occupied.
..1926.1053(b)(12)
1926.1053(b)(12)
Ladders shall have nonconductive siderails if they are
used where the employee or the ladder could contact exposed energized
electrical equipment, except as provided in 1926.951(c)(1) of this
part.
1926.1053(b)(13)
The top or top step of a stepladder shall not be used as a
step.
1926.1053(b)(14)
Cross-bracing on the rear section of stepladders shall not
be used for climbing unless the ladders are designed and provided with
steps for climbing on both front and rear sections.
1926.1053(b)(15)
Ladders shall be inspected by a competent person for
visible defects on a periodic basis and after any occurrence that could
affect their safe use.
1926.1053(b)(16)
Portable ladders with structural defects, such as, but not
limited to, broken or missing rungs, cleats, or steps, broken or split
rails, corroded components, or other faulty or defective components, shall
either be immediately marked in a manner that readily identifies them as
defective, or be tagged with "Do Not Use" or similar language, and shall
be withdrawn from service until repaired.
1926.1053(b)(17)
Fixed ladders with structural defects, such as, but not
limited to, broken or missing rungs, cleats, or steps, broken or split
rails, or corroded components, shall be withdrawn from service until
repaired. The requirement to withdraw a defective ladder from service is
satisfied if the ladder is either:
..1926.1053(b)(17)(i)
1926.1053(b)(17)(i)
Immediately tagged with "Do Not Use" or similar
language;
1926.1053(b)(17)(ii)
Marked in a manner that readily identifies it as
defective;
1926.1053(b)(17)(iii)
Or blocked (such as with a plywood attachment that spans
several rungs).
1926.1053(b)(18)
Ladder repairs shall restore the ladder to a condition
meeting its original design criteria, before the ladder is returned to
use.
1926.1053(b)(19)
Single-rail ladders shall not be used.
1926.1053(b)(20)
When ascending or descending a ladder, the user shall face
the ladder.
1926.1053(b)(21)
Each employee shall use at least one hand to grasp the
ladder when progressing up and/or down the ladder.
1926.1053(b)(22)
An employee shall not carry any object or load that could
cause the employee to lose balance and fall.
[55 FR 47689, Nov. 14, 1990; 56 FR 2585, Jan. 23, 1991; 56
FR 41794, Aug. 23, 1991]